引用本文: |
-
陈永欣,黎香荣,刘顺琼,唐梦奇.ICP-AES法同时测定冶炼渣浸出液中10种毒性元素[J].广西科学,2011,18(4):352-354. [点击复制]
- CHEN Yong-xin,LI Xiang-rong,LIU Shun-qiong,Tang Meng-qi.Simultaneous Determination of 10 Kinds of Toxic Elements from Smelting Slag Leaching Solution by ICP-AES Method[J].Guangxi Sciences,2011,18(4):352-354. [点击复制]
|
|
摘要: |
用浸取剂对冶炼渣样品进行浸提,浸出液经硝酸-盐酸消解后,电感耦合等离子体光谱测定消解液中的铜、锌、镉、铅、铬、铍、钡、镍、银和砷。方法的检出限低于0.065mg/L,加标回收率为88.9%~110.6%,相对标准偏差(n=6)为0.9%~4.9%。此方法具有检出限低、再现性好、分析效率高等优点,适用于冶炼渣浸出液中危害成分的测定。 |
关键词: 电感耦合等离子体发射光谱法 冶炼渣 浸出液 毒性元素 |
DOI: |
投稿时间:2011-01-07 |
基金项目:科技支承广西北部湾经济区发展专项(桂科转09320026);广西自然科学项目(桂科自0991295)资助 |
|
Simultaneous Determination of 10 Kinds of Toxic Elements from Smelting Slag Leaching Solution by ICP-AES Method |
CHEN Yong-xin, LI Xiang-rong, LIU Shun-qiong, Tang Meng-qi
|
(Fangchenggang Entry-Exit Inspection and Quarantine Bureau, Fangchenggang, Guangxi, 538001, China) |
Abstract: |
Hazardous ingredients such as copper, zinc, cadmium, lead, chromium, beryllium, barium, nickel, silver and arsenic in smelter slag were extracted with leach liquor, digested by HNO3-HCl solution, and determined by inductively coupled plasma atomic emission specrometry.Under the optical conditions, the detection limits were lower than 0.065 mg/L.The standard addition recoveries were 88.9%~110.6%, and the relative standard deviation (RSD, n=6) was 0.9%~4.9%.This method showed low detection limit of tested metals, good repetition, high analysis efficency and was applicable in the determination of hazardous ingredients in smelter slag. |
Key words: inductively coupled plasma atomic emission specrometry smelter slag maceration extract toxic element |